The Modbus protocol is a communication protocol that exists in various variants.
The WARP Charger supports Modbus/TCP
and acts as a Modbus server. Modbus is disabled by default.
Under the menu item Interfaces -> Modbus/TCP, Modbus can be activated and
configured.

It is possible to choose between Disabled, Read Only, and Read/Write
access:

Additionally, the Modbus/TCP port can be set and a register table can be selected:

Currently, the WARP Charger register table as well as
the register tables of Bender CC613 and the Keba C-Series are supported.
If one of the third-party register tables is selected, the WARP Charger simulates the corresponding register assignments of Bender and Keba. This allows a WARP Charger to be integrated into a home automation system or energy manager, etc. if they have support for one of the two third-party register tables.